PJG3 Miniature Spectral Illuminance Meter (Professional Version)

$278.00

The PJG3 series miniature spectral illuminance meter, developed using composite supermaterial and micro/nano-superficial technology, achieves miniaturization and lightweight design for spectral irradiance sensors. It can complete irradiance distribution, photometric parameters measurement, and illumination health analysis in one step. The product’s sleek and compact design, combined with standard serial communication protocol, facilitates independent use, integration with mobile devices, and secondary development. It is suitable for the R&D, quality inspection, and production line monitoring of display and lighting products, as well as for lighting measurements in various fields, buildings, and workplaces.

Domestic sales platform

Chinese users please choose domestic platforms

taobao

1 in stock

SKU: C910120011 Category:
Description

Product Details

The PJG3 series miniature spectral illuminance meter, developed using composite supermaterial and micro/nano-superficial technology, achieves miniaturization and lightweight design for spectral irradiance sensors. It can complete irradiance distribution, photometric parameters measurement, and illumination health analysis in one step. The product's sleek and compact design, combined with standard serial communication protocol, facilitates independent use, integration with mobile devices, and secondary development. It is suitable for the R&D, quality inspection, and production line monitoring of display and lighting products, as well as for lighting measurements in various fields, buildings, and workplaces.

Product Features

Comprehensive Parameters, Professional Performance, Precise Measurement Every Moment

Optical Parameters

  • 1
    Wavelength range
    340-800
    -
  • 2
    Output wavelength interval
    1
    -
  • 3
    Spectral resolution
    5@404 / 4@661 / 5@801
    -
  • 4
    Spectral accuracy (repeatability)
    ±1
    -
  • 5
    Digital dynamic range
    20bit
    -
  • 6
    Illumination range
    2-300000
    -
  • 7
    Signal-to-noise ratio
    300:1
    -
  • 8
    Color temperature range
    300-800000
    -
  • 9
    Color rendering index accuracy
    ±1
    -
  • 10
    Total illumination accuracy
    4%
    -
  • 11
    Chromaticity coordinate accuracy
    ±0.003
    -
  • 12
    Chromaticity coordinate repeatability
    ±0.001
    -

Performance Parameters

  • 13
    Frame rate
    10
    -
  • 14
    Integration time
    0.1-5000
    -
  • 15
    Power supply
    TTL4
    -
  • 16
    Compatible software
    win 10/11 x64 OS
    -
  • 17
    Mobile app
    None
    -
  • 18
    Operating temperature and humidity
    -10℃~45℃, humidity<80%
    -
  • 19
    User calibration
    Available
    -
  • 20
    Exposure time
    Manual exposure/auto exposure
    -
  • 21
    Measurement mode
    Manual measurement/automatic measurement
    -
  • 22
    Language mode
    Chinese/English
    -
  • 23
    File saving format
    Excel/PDF
    -
  • 24
    Automatic integration time adjustment
    -
    -
  • 25
    Continuous working duration
    -
    -

Connectivity & Dimensions

  • 26
    Dimensions
    28.5*30.5*20.5
    -
  • 27
    Weight
    15
    -
  • 28
    Shell material
    Plastic
    -
  • 29
    Waterproof and dustproof
    IP53
    -
  • 30
    Photoelectric sensors
    Area array CMOS
    -
  • 31
    Optical interface
    Φ11.8mm cosine corrector
    -
  • 32
    Data interface
    TTL4
    -

Standard Configuration

Standard Configuration
Additional information
Dimensions28.5 × 30.5 × 20.5 cm
Sale IDB32B4T08034CTPD
Product TypePlant lighting measurement
Structure CodeThird generation structure+European core grating
Irradiation AccuracyB
Resolution4
Parameter Output Type
End Wavelength80
Starting Wavelength34
Optical Structure
Shell materialPlastic
Spectral coverage range
operating system
Signal to Noise300
Specification

Measurable Parameters List

Category Parameters Symbol Unit
Basic Parameters
CIE1931 colorspace tristimulus values
X
Y
Z
CIE1931 colorspace chromaticity coordinates
x
y
CIE1960 colorspace chromaticity coordinates
u
v
CIE1976 colorspace chromaticity coordinates
u'
v'
Color temperature
CCT/Tc K
Color shift
Duv
Color render index
Ra,R1-15
Peak wavelength
Lp nm
Half-peak width
HW nm
Dominant wavelength
Ld nm
Color purity
Purity %
Color tolerance
SDCM
Light-dark vision ratio
S/P
Red ratio
R ratio %
Green ratio
G ratio %
Blue ratio
B ratio %
Illuminance
Lux lx
Irradiance
Ee W/m^2
Illuminance|(fc)
E(fc) Candela
Color quality scale
CQS
Gamut area index
GAI_EES
GAI_BB_8
GAI_BB_15
Equivalen melanopic lux
EML lx
Melanopic equivalent daylight illuminance
M_EDI lx
Plant Lighting Parameters
Photosynthetically active radiation
PAR W/m^2
Chlorophyll A weighted irradiance
Eca W/m^2
Chlorophyll B weighted irradiance
Ecb W/m^2
Blue purple irradiance
Eb W/m^2
Yellow green irradiance
Ey W/m^2
Red orange irradiance
Er W/m^2
Red blue irradiance ratio(%)
Erb_Ratio %
Photosynthetic photon flux density
PPFD umol/(m^2·s)
Blue purple photosynthetic photon flux density
PPFDb umol/(m^2·s)
Yellow green photosynthetic photon flux density
PPFDy umol/(m^2·s)
Red orange photosynthetic photon flux density
PPFDr umol/(m^2·s)
Far red photosynthetic photon flux density
PPFDfr umol/(m^2·s)
Red orange photosynthetic photon flux density ratio(%)
PPFDr_ratio %
Yellow green photosynthetic photon flux density ratio(%)
PPFDy_ratio %
Blue purple photosynthetic photon flux density ratio(%)
PPFDb_ratio %
Yield photon flux density
YPFD umol/(m^2·s)
TM30
Fidelity Index
Rf
Gamut Index
Rg

Technical Specifications

Category Parameters Specifications
Structural parameters Dimensions (mm) 28.5*30.5*20.5
Weight(g) 15
Material Plastic
Waterproof and dustproof IP53
Photoelectric Sensors Area array CMOS
Optical interface Φ11.8mm cosine corrector
Data Interface TTL4
Using Parameters Frame rate (fps) 10
Integration time (ms) 0.1-5000
Power TTL4
Supporting Software win 10/11 x64 OS
Mobile Client None
Optimum working temperature and humidity -10℃~45℃, humidity<80%
User calibration Available
Automatic adjustment function of integral time -
Exposure time Manual exposure/auto exposure
Measurement Mode Manual measurement/automatic measurement
Language Mode Chinese/English
File Saving Format Excel/PDF
Optical parameters Wavelength range (nm) 340-800nm
Spectral resolution (half peak width)(nm) 5@404 / 4@661 / 5@801
Output wavelength interval (nm) 1
Spectral accuracy(repeatability)(nm) ±1
Amplitude linearity -
Digital Dynamic Range 20bit
Illuminance measurement range (lux) 2-300000
Color temperature measurement range (K) 300-800000
Signal-to-Noise Ratio 300:1
Total illumination accuracy 4%
Chromaticity coordinate accuracy ±0.003
Chromaticity coordinate repeatability ±0.001
Supporting Software Measurement parameters Blue Light Hazard Irradiance (Eb)、Color Temperature (CCT)、Color Coordinates (x、y、u、v、u'、v')、Illuminance (lx)、Irradiance (Ee)、Color Rendering Index (Ra、R1-R15)、Color tolerance(SDCM)、Color Fidelity Index (Rf)、Color gamut Index (Rg)、Color Quality Scale (CQS)、Scotopic/Photopic Ratio (S/P)、Photosynthetically Active Radiation (PAR) Irradiance、Photosynthetic Photon Flux Density (PPFD)、Chlorophyll-weighted Irradiance、Near-infrared Spectrum Irradiance、etc.
TECH SUPPORT DOCUMENT
Shipping and Delivery

LOGISTICS & FULFILLMENT PARTNERSHIPS

To ensure your orders arrive safely and efficiently, we partner with leading international fulfillment providers who utilize the same robust logistics networks trusted by top global e-commerce platforms. By leveraging these world-class global supply chains, we provide reliable, secure, and optimized shipping solutions tailored to your destination.

SHIPPING & TRACKING POLICY

Reliable Order Processing: Orders are typically processed, quality-checked, and dispatched from the fulfillment center within 9–14 business days for shipments to the United States, within 10–15 business days for shipments to Canada, and within 7–12 business days for shipments to Europe.

End-to-End Tracking: Every shipment includes a dedicated tracking number, allowing you to monitor your package's journey from the automated sorting hub straight to your doorstep.

Estimated Delivery Windows: Delivery times vary depending on your local region and customs clearance. While our partners strive for rapid delivery, please note that international transits may occasionally experience minor delays due to regulatory checks or peak seasons.

FAQ

Q: Will I be charged customs duties or taxes?
A: Depending on your country's regulations, international shipments may be subject to import duties. These charges are the responsibility of the recipient.